Rotafix Timber resin structural repair
This period property was suffering from structural breakdown by wet rot decay to the horizontal timber beams over the cantilevered bay windows.
Large sections of the structural beams had decayed through the full width of the timber, City Remedial proposed a TG6 structural resin repair solution which was review approved by the structural engineers involved in the project.
First all decayed timber was removed back to sound timber, then carbon reinforcement bars were fixed to the sound timber with structural adhesive and tight fitting shuttering was installed to the areas ready for the pouring of the resin. The TG6 resin was carefully poured until the shuttering was filled in each section.
The solution represented a non intrusive, cost effective, and atheistically pleasing repair with the alternative being complete removal of the structural load bearing members, much disruption to tenants and internal making good.